# Active CRLH Transmission Line Modeler
|
||||
|
||||
A MATLAB simulation of an **active Composite Right/Left-Handed (CRLH) transmission line** with a frequency-dependent negative resistance element. The structure achieves controlled gain across a user-defined passband by embedding an active shunt element (modeled as a negative resistance `Rn`) within a periodic CRLH unit cell topology.
|
||||
This is supplemental code for the paper "Negative Resistance Enabled Amplifying CRLH Transmission Lines With Uniform Insertion Gain" (https://ieeexplore.ieee.org/document/11366944)
|
||||
---
|
||||
|
||||
## Background
|
||||
|
||||
CRLH transmission lines support both left-handed (LH) and right-handed (RH) wave propagation, enabling precise dispersion control. By introducing a frequency-shaped negative conductance into the shunt branch, this design compensates for losses and achieves net gain across the passband.
|
||||
|
||||
The unit cell uses a ** symmetric T-network topology** with:
|
||||
- **Series branch**: Right-handed inductance `LR` + left-handed capacitance `CL`
|
||||
- **Shunt branch**: Right-handed capacitance `CR` + left-handed inductance `LL` + active negative resistance `Rn(f)`
|
||||
|
||||
---
|
||||
|
||||
## Features
|
||||
|
||||
- Calculates CRLH element values (`LR`, `CR`, `LL`, `CL`) analytically from two frequency/phase design targets
|
||||
- Models frequency-dependent negative resistance as `Rn(f) = -A·exp(α·f)`, fit to desired shunt conductance at two frequencies
|
||||
- Cascades `n` unit cells in a **passive–active–passive** symmetric arrangement
|
||||
- Converts ABCD matrices to S-parameters
|
||||
- Plots:
|
||||
- Cascaded S-parameters (`S11`, `S21`)
|
||||
- Dispersion diagram (`βp` vs. frequency)
|
||||
- Shunt conductance vs. frequency
|
||||
- Required `Rn(f)` vs. exact analytical solutions
|
||||
- Single unit cell S-parameters with approximate insertion loss overlay
|
||||
- Bloch impedance (real and imaginary)
|
||||
- Outputs (in command window):
|
||||
- Constituent CRLH parameters
|
||||
- $R_n(\omega) exponential fit parameters
|
||||
- $S_{21}$ at desired frequencies ($\omega_1$ and $\omega_2$)
|
||||
- Maximum gain
|
||||
|
||||
---
|
||||
|
||||
## Dependencies
|
||||
|
||||
- [SPARAMS](https://github.com/njchorda/MATLAB-Touchstone-Reader) — provides `SPARAMS.abcd2s()` for ABCD-to-S-parameter conversion. Add as a submodule or clone separately and add to your MATLAB path.
|
||||
- `closestIdx` — a utility function for finding the nearest index in a vector. Included in the bottom of the main file.
|
||||
|
||||
After cloning, add dependencies to your MATLAB path
|
||||
---
|
||||
|
||||
## Usage
|
||||
|
||||
1. Open `Active_NRCRLH_Calcs.m` in MATLAB
|
||||
2. Set your design parameters in the **Input parameters** section:
|
||||
|
||||
| Parameter | Description |
|
||||
|-----------|-------------|
|
||||
| `f1`, `f2` | Lower and upper frequency bounds of the passband (Hz) |
|
||||
| `theta1`, `theta2` | Desired phase shifts at `f1` and `f2` (rad) |
|
||||
| `n` | Number of unit cells (must be **odd** for passive–active–passive symmetry) |
|
||||
| `Z0` | Reference impedance (default: 50 Ω) |
|
||||
| `G_desired` | Target shunt conductance (set as a fraction of `G_max`) |
|
||||
|
||||
3. Run the script — six figures will be generated automatically. You may need to tune the figX.Position parameter to fit them on your screen
|
||||
|
||||
---
|
||||
|
||||
## Design Equations
|
||||
|
||||
CRLH element values are solved analytically from the two phase/frequency constraints:
|
||||
|
||||
$$L_R = \frac{Z_0(\theta_1 \frac{\omega_1}{\omega_2} - \theta_2)}{n\,\omega_2\!\left(1 - \left(\frac{\omega_1}{\omega_2}\right)^2\right)}$$
|
||||
|
||||
$$C_R = \frac{\theta_1 \frac{\omega_1}{\omega_2} - \theta_2}{n\,\omega_2 Z_0\!\left(1 - \left(\frac{\omega_1}{\omega_2}\right)^2\right)}$$
|
||||
|
||||
with symmetric expressions for `LL` and `CL`.
|
||||
|
||||
The required negative resistance at each frequency satisfies:
|
||||
|
||||
$$G_{sh} = \frac{R_n}{R_n^2 + (\omega L_L)^2}$$
|
||||
|
||||
which is solved exactly at `f1` and `f2`, then fit with an exponential model across the full band.
|
||||
|
||||
---
|
||||
|
||||
## Output Figures
|
||||
|
||||
| Figure | Contents |
|
||||
|--------|----------|
|
||||
| 1 | Cascaded `S11` and `S21` (dB) |
|
||||
| 2 | Dispersion: `βp` (deg) vs. frequency |
|
||||
| 3 | Shunt conductance `G(f)` vs. frequency |
|
||||
| 4 | `Rn(f)`: exponential fit vs. exact analytical solutions |
|
||||
| 5 | Single unit cell S-parameters + approximate `S21` |
|
||||
| 6 | Bloch impedance `ZB` (real and imaginary) |
|
||||
|
||||
---
|
||||
|
||||
## Notes
|
||||
|
||||
- `n` must be **odd** to maintain the passive–active–passive cascade symmetry
|
||||
- Loss-balanced condition (`Gsh = Rse/Z0²`) is available but commented out by default
|
||||
- The Rollett (K-Δ) stability analysis block is present in the code but commented out — uncomment to assess unconditional stability across frequency
|
||||
- Maximum achievable gain is estimated from the loss parameters and printed to the console on each run
|
||||
|
||||
---
|
||||
|
||||
## License
|
||||
|
||||
MIT License — see `LICENSE` for details.
|
||||
Reference in New Issue