Agilent34405A — MATLAB Instrument Driver

A MATLAB class for controlling the Agilent 34405A bench multimeter over USB/VISA. Provides a clean, object-oriented interface for all major measurement modes, configuration, and instrument lifecycle management.


Requirements

  • MATLAB with the Instrument Control Toolbox
  • NI-VISA driver installed
  • Agilent34405AStates enumeration class (companion file)

Installation

  1. Clone or download this repository.
  2. Add the folder to your MATLAB path:
    addpath('/path/to/Agilent34405A');
    
  3. Ensure the multimeter is connected via USB and recognized by NI-VISA.

Quick Start

% Instantiate — automatically finds the instrument via USB
dmm = Agilent34405A();

% Read DC voltage
v = dmm.readDCV();

% Read AC current
i = dmm.readACI();

% Read temperature
t = dmm.readTemp();

% Clean up when done
dmm.deInit();

Supported Measurement Modes

Method Description
readDCV() DC Voltage
readACV() AC Voltage
readDCI() DC Current
readACI() AC Current
readTemp() Temperature
read2WRes() 2-Wire Resistance
readCont() Continuity
readDiode() Diode Test
readCapacitance() Capacitance
readFrequency() Frequency
readPeriod() Period
scan() Scan mode

All measurement methods automatically switch the instrument to the correct mode if it isn't already configured.


Configuration & Utilities

Set Measurement Scale

% obj.setScale(state_string, [resolution, range])
dmm.setScale('VOLT:DC', [0.001, 10]);

Trigger & Sample Settings

dmm.sampleCount  = 20;   % Number of samples (default: 10)
dmm.triggerCount = 4;    % Trigger count (default: 1)

dmm.setSampleCount();    % Apply sample count to instrument
dmm.setTriggerCount();   % Apply trigger count to instrument
dmm.setTriggerSource('BUS');  % Set trigger source

Send Arbitrary SCPI Command

% Automatically reads response if command contains '?'
response = dmm.sendCommand('VOLT:DC:RANG?');
dmm.sendCommand('DISP:TEXT "Hello"');

Other Utilities

dmm.getConfig()       % Query current instrument configuration
dmm.selfTest()        % Run built-in self-test and print result
dmm.reset()           % Send *RST to instrument
dmm.setBeep(true)     % Enable/disable beeper
dmm.setLocal()        % Return front-panel control to user
dmm.approxTime(state) % Benchmark acquisition time for a given state
dmm.deInit()          % Cleanly close and release the VISA connection

Properties

Property Default Description
visaAddress (auto-detected) USB/VISA address of the instrument
state DCV Current measurement mode
numSamples 512 Internal sample buffer size
sampleCount 10 Samples per trigger sent to instrument
triggerCount 8 Number of triggers

Notes

  • The constructor automatically detects the instrument address using instrhwinfo('visa','ni') — no manual address configuration needed.
  • The beeper is silenced on startup by default.
  • deInit() should always be called when finished to cleanly release the VISA resource.

License

MIT License — see LICENSE for details.